一、 Summary
A central collector is a commonly used device that supplies power to rotating mechanisms. It can transmit electricity to rotating equipment, and current is transmitted to copper alloy rings through carbon brushes. According to different models of the device, in order to ensure maximum surface contact and stable current, we use a variable unique spring design to ensure constant contact between the carbon brush and the slip ring. Used in various door machines for power transmission and signal transmission when relative components move in a circular motion. Our products are available in major ports, docks, power stations, water conservancy engineering, mining, metallurgical and other industrial and mining enterprises across the country.
二、Adopting standards
IEC 60204-32:1998 "Electrical specifications for crane machinery"
GB14048.1 "General Principles for Low Voltage Switchgear and Control Equipment"
JT/T70.2-93 "Technical Conditions for Electric Control Equipment of Port Portal Crane - Collector"
三、Product series and model description
This product is a series of upper and lower transmission modes and control ring types, with specifications based on ring current capacity and number of rings
四、Product appearance and installation dimensions
Table of Key Dimensions and Ring Current Ratings
Transmission mode |
model |
Thread diameter ¥ A |
Installation aperture ¥ B |
Boundary dimension C |
Outer diameter of transmission claw ¥ D |
Slip ring current rating |
|||
Lower transmission |
ZS-C61 |
140 |
380 |
425 |
200 |
- |
400A |
63A |
- |
ZS-C1 |
140 |
380 |
425 |
200 |
- |
400A |
63A |
10A |
|
ZS-C3 |
190 |
450 |
500 |
260 |
630A |
- |
63A |
10A |
|
Upper transmission |
ZS-C62 |
140 |
380 |
425 |
200 |
- |
400A |
63A |
- |
ZS-C2 |
140 |
380 |
425 |
200 |
- |
400A |
63A |
10A |
|
ZS-C4 |
190 |
450 |
500 |
260 |
630A |
- |
63A |
10A |
Carbon brush and conductive configuration wire
|
Single ring carrying current (A) |
Configuration wire cross-sectional area mm ² |
Number of carbon brushes configured (pairs) |
Large slip ring |
630 |
150 |
3 |
400 |
120 |
3 |
|
Middle slip ring |
63 |
16 |
2 |
Small slip ring |
10 |
2.5 |
1 |
Table of values for the number of slip rings n
Collector model n |
ZS-C1 |
ZS-C2 |
ZS-C3 |
ZS-C4 |
ZS-C61 |
ZS-C62 |
630A |
- |
- |
1~10 |
1~10 |
- |
- |
400A |
1~10 |
1~10 |
- |
- |
1~10 |
1~10 |
63A |
1~40 |
1~40 |
1~40 |
1~40 |
1~50 |
1~50 |
10A |
1~60 |
1~60 |
1~60 |
1~60 |
- |
- |
五、Usage and maintenance
The central collector should be installed vertically, and the drive plate protrusion should be correctly installed in the drive groove of the crane. The axis of rotation of the central collector coincides with the axis of rotation of the crane, and the allowable deviation is not more than 1/1000 of the total height of the central collector.
Before using the central collector, it is necessary to check whether each wiring terminal is tightly pressed, whether the carbon brush is in good contact with the slip ring, and whether there is any jamming phenomenon.
Regular inspections should be carried out to check the wear of the carbon brushes, remove any powder that has fallen from the worn brushes, and replace them with new ones if necessary. Inject butter between the rotating parts. When the central collector is not in use temporarily, the environment should be kept dry.
六、Ordering Instructions
Indicate the model, installation method, current rating of each ring required, and corresponding number of rings
Do you want double loop parallel connection
Are there any special requirements for wiring
Is there a requirement for wire number markings on the wiring board
Do you need to add a protective cover
Is ship inspection required
If a high and low voltage mixed central collector is required, it can be specially customized according to requirements